Rent the TVA2020 Thermo Fisher Toxic Vapor Analyzer.

The TVA2020 Toxic Vapor Analyzer by Thermo Fisher Scientific helps you quickly detect fugitive emmisons of organic and inorganic compounds. The Toxic Vapor Analyzer is the only intrinsically safe, portable filed analyzer using both Flame Ionization Detection (FID) and Photo Ionization Detection (PID). It is capable of detecting virtually all organic and inorganic compounds. This is a light-weight design helps reduce fatigue for true portability and is easier to service in the field. The TVA2020 comes with a variety of options including an enhanced probe. Rent yourself one today!

TVA2020 Specifications 

TVA2020 Toxic Vapor Analyzer Includes:

  • - TVA2020 Dual Detection (PID & FID)
  • - Pelican Case
  • - Power Supply
  • - Unit Cable Charger
  • - USB Cable / USB Barrier Device
  • - 2(each) Hydrogen Tanks
  • - Enhanced Probe Assembly
  • - Water Trap Filters
  • - Shoulder Strap
  • - Hardware Kit
  • - Probe Connector Cap
  • - Hydrogen Tank Fill Adapter
  • - Printed Full Manual
  • - Calibration Certificate

Specifications
Accuracy FID Instrument–±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm 
PID Instrument–±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm
Components Measured Most organic and inorganic compounds
Computer Requirements USB port, Windows XP operating system or higher
Concentration Measurement Range FID: 0-30,000 ppm (methane)PID: 0-2,000 ppm (isobutylene)
Data Logging Averaging Periods Auto mode - 1 per second to 1 per 999 minutes, user selectable
VOC or FE Mode - 2 to 30 seconds, user selectable
Description TVA2020 Toxic Vapor Analyzer
Flow Rate 1L/min., nominal at sample probe inlet
Height (English) 11.5 in
Hertz 50/60
Inputs BluetoothTM, USB
Depth (English) 4 in.
Outputs BluetoothTM, USB
Repeatability FID Instrument +/- 2% at 500 ppm of methane 
PID Instrument +/- 1% at 100 ppm of isobutylene
Serial Interface USB
Voltage 100-230 V
Weight (English) FID only—9.2 pounds
Dual—9.4 pounds
Width (English) 9 in
Battery Life The battery operating time is 10 hours minimum at 0 °C (32 °F). Fully charged in less than 10 hours.
Battery Type Lithium ion
Calibration Kit Part Number for FID: CR009UY 
Part Number for dual detector: CR012UH
Fuel 99.99% H2 for FID
Portable Operation Time Minimum 10 hours
Response Time PID Instrument - Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene 
FID Instrument - Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane
Temperature (English) Range 14° F - 113° F