The Honeywell BW™ Ultra is a portable five gas detector from Honeywell that is designed specifically for sampling and monitoring confined spaces, before and after entry. Its benefits include 1-Series sensor technology, visibility on gas readings, comfort, and connectivity in even the most extreme working conditions. The Honeywell BW™ Ultra simultaneously detects the four gases you’re required to monitor in confined spaces. Plus there is a fifth sensor for the gas of your choice. This way you can add a fifth level of protection for your confined-space entries.
Unlike gas detectors that you wear, the Honeywell BW™ Ultra is a multi-gas detector that you hold as you sample the air in a confined space. That’s why the Honeywell BW™ Ultra has been designed with a slimmer profile to fit the shape of your hand to help minimize fatigue and enhance productivity. Plus it has the one-button operation and easy user friendly experience you’ve come to expect from Honeywell detectors. If you do need to wear the Honeywell BW™ Ultra as you navigate a tight space, the detector moves with you with an internal pump and no snag points. The Honeywell BW™ Ultra fully complies with all safety regulations in place so you can add the maximum level of protection for your confined space entries.
Optional Ultra Deluxe Confined Space Kit Includes: - Sturdy plastic carrying case - 10ft/3m Tygon Sampling Hose - 3ft/1m Hose - Concusion-Proof Boot - Sampling Probe - Ultra Toolkit - IR Connectivity Kit with Fleet Manager II Software - Carrying Holster
Activated detectors automatically perform one internal diagnostic test every 24 hours (sensors, battery, and circuitry).
Typical Battery Life
18 hours (14 hours with PID or IR sensor) @ -4° F / -20° C
Pump Draw
Sample from up to 75 ft. / 22.9 m
Connected Worker
• Bluetooth™ Low Energy (BLE) – Ability to connect to Honeywell’s Safety Communicator App • Honeywell TouchConnect™ – Easy ability to enter Bump or Calibration mode or change Set-Points
Event Logging
30 alarm events and 10 bump events
Data Logging
45 days based on 8 hour shifts every 15 seconds logging
User Options
• Adjust STEL period (5-15 minutes in 1 minute intervals) • Calibration span levels • Calibration interval • Bump test interval • Select combustible gases measurement: 0-100% LEL (Lower Explosive Limit) or Methane gas 0-5.0% v/v • LEL and PID correction factors • Calibration due date (1 to 365 days, or set to zero for off) • Individual sensor enable/disable • Latching alarms • Stealth mode • Languages: English, French, German, Portuguese, Spanish, Simplified Chinese and Russian
Certifications and Approvals
UL: Class I, Div 1, Group A, B, C, D Class I, Zone 0, Group IIC ATEX: II 1G Ex ia IIC T4 Ga IECEx: Ex ia IIC T4 Ga CE: European Conformity
Warranty
Instrument: 3 years Sensors: 3 years (2 years NH3, 1 year PID and Cl2) Battery: 2 years
Sensor Specifications
Gases
Range
Resolution
Oxygen (O2)
0-25% vol.
0.1% vol.
Combustible Gases (LEL)
0.100% LEL
1%
Combustible Gases (IR)*
0-5.00% vol.
0.01% vol.
Hydrogen Sulfide (H2S)
0-100 ppm
1 ppm / 0.1 ppm
Carbon Monoxide (CO)
0-2000 ppm
1 ppm
Carbon Monoxide (Low H2) (CO-H)
0-1000 ppm
1 ppm
Sulfur Dioxide (SO2)
0-100 ppm
0.1 ppm
Hydrogen (H2)
0-2000 ppm
5 ppm
Carbon Dioxide (CO2)
0-50000 ppm
100 ppm
Ammonia (NH3)
0-100 ppm
1 ppm
Volatile Organic Compounds (VOC)
0-1000 ppm
1 ppm
Chlorine (CL2)
0-20 ppm
0.1 ppm
Nitrogen Dioxide (NO2)
0-50 ppm
0.1 ppm
Hydrogen Cyanide (HCN)
0-100 ppm
0.1 ppm
Nitrogen Monoxide (NO)
0-200 ppm
1 ppm
*Caution: the LEL IR combustible gas sensor option used in Honeywell BW™ Ultra cannot detect certain combustible gases including hydrogen and acetylene. The application should be reviewed to ensure the Honeywell BW™ Ultra can provide adequate detection.
-Large, easy-to-view screen -The new 1-Series sensor for enhanced reliability -Honeywell TouchConnect™ Technology compatible for quick instrument management -Remote monitoring for an additional layer of protection.