Honeywell Fire Sentry FS24X 110° Field of View Fire and Flame Detector

Honeywell Fire Sentry FS24X 110° Field of View Fire and Flame Detector

Honeywell Fire Sentry SS4 Fire and Flame Detectors

Honeywell Fire Sentry SS4 Fire and Flame Detectors

Honeywell Fire Sentry FS20X Fire and Flame Detectors

$0.00
SKU
FS20X

Honeywell Analytics Fire Sentry FS20X Fire and Flame Detectors.
 

The Fire Sentry FS20X is the latest generation high technology Multi-Spectrum (UV/Dual IR/VIS) Fire and Flame Detector, which is part of the FSX family of advanced technology Electro-Optical Flame detectors.

Based on the foundation of the highly successful and reliable Fire Sentry SS4 detector, the Fire Sentry FS20X detector represents a quantum leap in integrating Infrared and Ultraviolet sensing technologies. The Fire Sentry FS20X is a Multi-Spectrum and UV/Dual IR/VIS fire and flame detector with a proven UV solar-blind sensor. The Fire Sentry FS20X exhibits faster false-alarm free response to fires over a wider temperature range and with a much longer detection range compared to conventional UV/IR detectors.

Conventional and older technology UV/IR detectors, using narrow band 4.3 micron IR sensors, will not respond to smoky fires or if the detector lens is contaminated with oil and other substances since both UV and 4.3 micron signals are attenuated, obscured or absorbed by thick smoke or detector lens contaminations. Also, these old technology UV/IR detectors will not alarm to any fire if they are installed behind ordinary window glass.

The Fire Sentry FS20X detector uses advanced patented algorithms for signal processing and fire and flame analysis is designed to alarm to all types of fires in all industrial environmental conditions. If the detector’s UV signal is degraded due to heavy smoke or a contaminated lens, the Fire Sentry FS20X’s patented* WideBand IR™, Near Band IR and Visible sensors will still alarm to fire but at a reduced sensitivity and slower response time.

Dual microprocessors provide a high level of fail-safe operation combined with fast and reliable performance. The Master Microprocessor performs high-speed digital sampling and signal processing calculations; while the slave microprocessor handles various sensor data, performs communications, self-diagnostics and provides interface versatility; and additional memory for storing Event Log and FirePic™ data.

The Fire Sentry FS20X detector has a detection range in excess of 200 feet (very high sensitivity setting) for the detection of a one square-foot Heptane reference fire and has a cone of vision greater in volumetric coverage than most UV/IR detectors. This means fewer detectors can be used as compared to other manufacturers’ detectors.

Honeywell FS20X Datasheet

Honeywell FS20X Specifications

MODEL FS20X-211 Series Standard Temp Range -40°F (-40°C) to 185°F (85°C)

Part Number Description
FS20X-211-21-2 Dual IR/UV Detector Copper-Free Aluminum Enclosure, w/ (2) 3/4" NPT Entries
FS20X-211-22-2 Dual IR/UV Detector 316 Stainless Steel Enclosure w/ (2) 3/4" NPT Entries
FS20X-211-23-2 Dual IR/UV Detector Copper-Free Aluminum Enclosure w/ (2) M25 (25mm) Entries
FS20X-211-24-2 Dual IR/UV Detector 316 Stainless Steel Enclosure w/ (2) M25 (25mm) Entries

MODEL FS20X-212 Series w/HART Standard Temp Range -40°F (-40°C) to 185°F (85°C)

Part Number Description
FS20X-212-21-2 Dual IR/UV Detector Copper-Free Aluminum Enclosure, w/ (2) 3/4" NPT Entries, HART Module
FS20X-212-22-2 Dual IR/UV Detector 316 Stainless Steel Enclosure w/ (2) 3/4" NPT Entries, HART Module

Features

  • -Patented* WideBand IR™ Infrared combined with Ultraviolet
  • -Detection range greater than 200 feet to 1 sq. ft. heptane fire
  • -Patented* Electronic Frequency Analysis
  • -Visible Sensor for optimum false alarm rejection
  • -Selectable detection sensitivities
  • -Solar blind 90° full 100% cone-of-vision
  • -Dual Microprocessors for reliable performance
  • -Real-time clock for accurate time dating of events
  • -FirePic™ — Up to 6 pre-fire event data storage
  • -Event log — Up to 200 events with date and time stamp
  • -Built-in RS-485 ModBus Communication
  • -Built-in non-isolated 4-20 mA analog output (sink or source)
  • -Alarm, Fault and Fire Verification relays.
  • -Automatic Optical Path and Electronic Self-Test
  • -Widest operating temperature range
  • -Patented* Electronics Module for components protection with plug-in terminations for easy field installation
  • -Two ¾” NPT OR 25mm conduit entries
  • -Low power consumption
  • -High RFI and EMI immunity
  • -FM approved

Benefits

  • -Detects hydrocarbon and non-hydrocarbon fuel fires in all environmental conditions
  • -Arc welding immunity
  • -False alarm rejection for all environmental conditions
  • -Minimal maintenance for trouble-free operation
  • -PC software and Interface Module (FSIM) for fault diagnostics real-time graphs (RTGs), and downloading of FirePics™ and event log
  • -Suitable for a wide variety of applications