Make the 301C controller the centerpiece for your buildings gas detection network. This controllers offers safety, energy efficiency and easy installation. The 301C controller continously monitors and controls toxic, combustible and refridgerant gasses as well as oxygen. The controller is user friendly with zero maintenance, an automatic quick self-test and warm-up and continous alphanumeric display. With low installation costs its also reliable and energy efficent by allowing up to 126 zoning groups which can help you save energy and extend fan and relay life. Manage up to 180 events with programmable latching alarms.
General Specification | |
Use | Controller for centeralized gas detection monitoring with real-time gas reading, selective alarm activiation and low cost installation |
Power Requirement | 17-27 VAC, 24-38 VDC, 500mA |
Size | 11 (W) x 8 (H) x 2.8 (D) in. (28 x 20.3 x 7 cm) |
Weight | 2.4 Lbs. |
Network Capacity | Three RS-485 channes for up to 96 transmitter inputs |
Digital Communication | Optional BACnet/IP interface, BTL listed as a smart sensor |
Communication Line Lengths | Up to 2,000 ft. (609 m) per channel T-Tap: 65 ft. (20 m), maximum per T-Tap 130 ft. (40 m), maximum for all T-Tap combined |
Relay Output | 5 A, 30 VDC or 250 VAC (resistive load) |
Alarm Levels | Four fully programmable alarm levels |
Time Delays | 0, 30 sec, 45 sec, 1-99 minutes before and after alarm |
Outputs | 4 DPDT relays (alarms and/or fault); 65dBA buzzer |
Events | Flexible programming that can include: gas concentrations, faults, real time clock, voting, optional outlier detection and time since calibration |
Display | Large 122 x 32 dot matrix display |
Operating Humidity Range | 0 to 95% RH ( non-condensing) |
Operating Temperature Range | -4° to 122°F (-20° to 50°C) |
Security | Password protection for tamper resistance |
Zoning | Up to 126 programmable zones |
Optional Memory | 2GB removable SD Card for configuration,readings, and events |
Ratings and Certification | |
Certified to | For USA: Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part 1: General Requirements (ANSI/UL 61010-1, 2nd Edition, Dated July 12, 2004 Including Revisions Through October 28, 2008) For Canada: Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part 1: General Requirements (CAN/CSA C22.2 No. 61010-1:04, 2nd Edition, Dated July 12, 2004 Including General Instruction 1 – October 2008 (Reaffirmed 2009)) |
Certified By | Intertek |
Designed to comply with | IEC 61010-1:2010 (Third Edition) California Title 24, Part 6, and associated administrative regulations In Part 1 |
Features:
- User Friendly
- Zero Maintenance
- Low Installation Costs
- Automatic Quick Self-Test & Warm-Up
- Allows Up to 126 Zoning Groups
- Manages 180 events with programmable latching alarms
- Programmable Time Delays
- Expands to Handle Up to 96 Tranmitters or relay modules