The Honeywell BW™ Ultra is a portable five gas detector from Honeywell that is designed specifically for sampling and monitoring confined spaces, before and after entry. Its benefits include 1-Series sensor technology, visibility on gas readings, comfort, and connectivity in even the most extreme working conditions. The Honeywell BW™ Ultra simultaneously detects the four gases you’re required to monitor in confined spaces. Plus there is a fifth sensor for the gas of your choice. This way you can add a fifth level of protection for your confined-space entries.

Unlike gas detectors that you wear, the Honeywell BW™ Ultra is a multi-gas detector that you hold as you sample the air in a confined space. That’s why the Honeywell BW™ Ultra has been designed with a slimmer profile to fit the shape of your hand to help minimize fatigue and enhance productivity. Plus it has the one-button operation and easy user friendly experience you’ve come to expect from Honeywell detectors. If you do need to wear the Honeywell BW™ Ultra as you navigate a tight space, the detector moves with you with an internal pump and no snag points. The Honeywell BW™ Ultra fully complies with all safety regulations in place so you can add the maximum level of protection for your confined space entries.

Optional Ultra Deluxe Confined Space Kit Includes:
- Sturdy plastic carrying case
- 10ft/3m Tygon Sampling Hose
- 3ft/1m Hose
- Concusion-Proof Boot
- Sampling Probe
- Ultra Toolkit
- IR Connectivity Kit with Fleet Manager II Software

- Carrying Holster



Technical Specifications

Specifications
Size 5.8 x 3.3 x 1.6 in. / 14.8 x 8.5 x 4.0 cm
Weight 14.5 oz. / 411 g (with clip)
Operating Temperature -4 to +131° F / -20 to +50° C
Humidity 5 - 95% RH (non-condensing) continuous
Ingress Protection IP66/68
Alarms and Type Visual, vibrating, audible (95 dB); Low, High, TWA, STEL, OL (over limit)
Self-Test Activated detectors automatically perform one internal diagnostic
test every 24 hours (sensors, battery, and circuitry).
Typical Battery Life 18 hours (14 hours with PID or IR sensor) @ -4° F / -20° C
Pump Draw Sample from up to 75 ft. / 22.9 m
Connected Worker • Bluetooth™ Low Energy (BLE) – Ability to connect
to Honeywell’s Safety Communicator App
• Honeywell TouchConnect™ – Easy ability to enter
Bump or Calibration mode or change Set-Points
Event Logging 30 alarm events and 10 bump events
Data Logging 45 days based on 8 hour shifts every 15 seconds logging
User Options • Adjust STEL period (5-15 minutes in 1 minute intervals)
• Calibration span levels
• Calibration interval
• Bump test interval
• Select combustible gases measurement: 0-100% LEL
(Lower Explosive Limit) or Methane gas 0-5.0% v/v
• LEL and PID correction factors
• Calibration due date (1 to 365 days, or set to zero for off)
• Individual sensor enable/disable
• Latching alarms
• Stealth mode
• Languages: English, French, German, Portuguese,
Spanish, Simplified Chinese and Russian
Certifications and Approvals UL: Class I, Div 1, Group A, B, C, D
Class I, Zone 0, Group IIC
ATEX: II 1G Ex ia IIC T4 Ga
IECEx: Ex ia IIC T4 Ga
CE: European Conformity
Warranty Instrument: 3 years
Sensors: 3 years (2 years NH3, 1 year PID and Cl2)
Battery: 2 years

 

Sensor Specifications

 Gases Range Resolution
 Oxygen (O2) 0-25% vol. 0.1% vol.
 Combustible Gases (LEL) 0.100% LEL 1%
 Combustible Gases (IR)* 0-5.00% vol. 0.01% vol.
Hydrogen Sulfide (H2S) 0-100 ppm 1 ppm / 0.1 ppm
Carbon Monoxide (CO) 0-2000 ppm 1 ppm
Carbon Monoxide (Low H2) (CO-H) 0-1000 ppm 1 ppm
 Sulfur Dioxide (SO2) 0-100 ppm 0.1 ppm
 Hydrogen (H2) 0-2000 ppm 5 ppm
Carbon Dioxide (CO2) 0-50000 ppm 100 ppm
 Ammonia (NH3) 0-100 ppm 1 ppm
Volatile Organic Compounds (VOC)  0-1000 ppm 1 ppm
Chlorine (CL2) 0-20 ppm 0.1 ppm
Nitrogen Dioxide (NO2) 0-50 ppm 0.1 ppm
Hydrogen Cyanide (HCN) 0-100 ppm 0.1 ppm
Nitrogen Monoxide (NO) 0-200 ppm 1 ppm

*Caution: the LEL IR combustible gas sensor option used in Honeywell BW™ Ultra cannot detect certain combustible gases including hydrogen and acetylene. The application should be reviewed to ensure the Honeywell BW™ Ultra can provide adequate detection.

BW Honeywell Ultra 5 Gas Detector Specifications Data Sheet

 

Features

-Large, easy-to-view screen
-The new 1-Series sensor for enhanced reliability
-Honeywell TouchConnect™ Technology compatible for quick instrument management
-Remote monitoring for an additional layer of protection.